| 7101 | Furnace I | 29 May 2021 | 11:10:00 pm | 11:30:00 pm | 0h 20min | Due to Ele no 1 sparking so tightening the bolts | |
| 7102 | Furnace I | 28 May 2021 | 08:15:00 am | 09:00:00 am | 1h 15min | Due to E2 sparking problem we put pest inside the clamp and it was ok. | |
| 7103 | Furnace I | 28 May 2021 | 06:40:00 am | 07:45:00 am | 1h 5min | Due to E2 B4 spring changing and B5,B6 insulation changing | |
| 7104 | Furnace I | 28 May 2021 | 08:00:00 pm | 08:10:00 pm | 0h 10min | E1 sparking and bolt tighting | |
| 7105 | Furnace II | 27 May 2021 | 02:10:00 pm | 02:30:00 pm | 0h 20min | Due to electrode no3 bolt came out when tighting | |
| 7106 | Furnace I | 27 May 2021 | 08:25:00 pm | 08:35:00 pm | 0h 10min | Electrode length checking. | |
| 7107 | Furnace II | 26 May 2021 | 11:05:00 am | 11:15:00 am | 0h 10min | Due to incomer over current trip | |
| 7108 | Furnace I | 26 May 2021 | 11:05:00 am | 11:15:00 am | 0h 10min | Due to incomer over current trip |