| # | Furnace | Date | From | To | Duration | Remarks | |
|---|---|---|---|---|---|---|---|
| 5981 | Furnace II | 17 Apr 2022 | 08:45:00 pm | 09:00:00 pm | 0h 15min | Due to E1 a3 clamp water leakage and sparking problem | |
| 5982 | Furnace I | 17 Apr 2022 | 11:05:00 am | 11:25:00 am | 0h 20min | Electrode no.3 seal box hose pipe water leakage | |
| 5983 | Furnace I | 17 Apr 2022 | 09:00:00 am | 09:55:00 am | 1h 5min | Electrode no.1 A1 clamp hose pipe came out and outlet water blocked it was repaired | |
| 5984 | Furnace II | 15 Apr 2022 | 09:00:00 pm | 09:40:00 pm | 1h 20min | Due to electrodes no1 blower is not working | |
| 5985 | Furnace II | 15 Apr 2022 | 09:20:00 am | 10:00:00 am | 1h 20min | Due to Zesco power failure | |
| 5986 | Furnace I | 15 Apr 2022 | 09:20:00 am | 10:00:00 am | 1h 20min | Due to Zesco power failure | |
| 5987 | Furnace II | 14 Apr 2022 | 03:00:00 pm | 07:15:00 pm | 4h 15min | Due to furnace 2 11kv outgoing CT control wire short circuit | |
| 5988 | Furnace I | 14 Apr 2022 | 03:00:00 pm | 07:15:00 pm | 4h 15min | Due to furnace 2 11kv outgoing CT control wire short circuit |