Shutdowns

Showing 5,981-5,988 of 7,425 items.
#FurnaceDateFromToDurationRemarks 
     
5981Furnace II17 Apr 202208:45:00 pm09:00:00 pm0h 15minDue to E1 a3 clamp water leakage and sparking problem
5982Furnace I17 Apr 202211:05:00 am11:25:00 am0h 20minElectrode no.3 seal box hose pipe water leakage
5983Furnace I17 Apr 202209:00:00 am09:55:00 am1h 5minElectrode no.1 A1 clamp hose pipe came out and outlet water blocked it was repaired
5984Furnace II15 Apr 202209:00:00 pm09:40:00 pm1h 20minDue to electrodes no1 blower is not working
5985Furnace II15 Apr 202209:20:00 am10:00:00 am1h 20minDue to Zesco power failure
5986Furnace I15 Apr 202209:20:00 am10:00:00 am1h 20minDue to Zesco power failure
5987Furnace II14 Apr 202203:00:00 pm07:15:00 pm4h 15minDue to furnace 2 11kv outgoing CT control wire short circuit
5988Furnace I14 Apr 202203:00:00 pm07:15:00 pm4h 15minDue to furnace 2 11kv outgoing CT control wire short circuit