Maintenance Report

Search Filter:

Showing 16,421-16,430 of 17,159 items.

#DateTypeDetailsFurnaceEquipmentActions
1642129 Apr 2020Scheduled MaintenanceLT.
1. motor condition is good. ( amp, volt, and connectivity). no noise coming.
2. checked panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. checked limit switches and its condition.

CT.
1. motor condition is good. ( amp, volt, and connectivity). no noise coming.
2. checked panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. checked limit switches and its condition.

HT.
1. motor condition is good. ( amp, volt, and connectivity). no noise coming.
2. checked panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. checked limit switches and its condition.
OtherTAPPING SEC. CRANE NO. 3
1642229 Apr 2020Breakdown MaintenanceIt's pipe is damaged so we cut it and fix the problem.OtherPOLLUTION 2
1642328 Apr 2020Otherfor Mansa
floating drum work is complete.
OtherOTHERS
1642428 Apr 2020Scheduled MaintenanceWATER CIRCULATION PUMP 1
FURNACE 1
GRANULATION PUMP 1,2
POLLUTION WATER PUMP NO 1

FURNACE 2
GRANULATION PUMP 1,2,
POLLUTION WATER PUMP NO 1,
WASHING PLANT SUBMERSIBLE PUMP 1

1. checked the pump condition and check discharge.it is ok.
2. checked coupling condition, alignment, and greasing are done.
3. checked pipelines and valve's condition.it is ok.
4. checked cooling towers nozzles condition. we change 3 nozzles of the cooling tower.
OtherPUMP
1642528 Apr 2020Scheduled MaintenanceF1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, POLLUTION WATER PUMP MOTOR
NO 1

F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1,
WASHING PLANT SUBMERSIBLE PUMP MOTOR1

1. checked the motor condition. no noise coming.
2. checked panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. water circulation pump motor greasing.is done.
OtherPUMP
1642628 Apr 2020Breakdown MaintenanceShifting Limit switch of baching conveyor is not working so we change it.OtherRMHS CONVEYOR
1642728 Apr 2020Breakdown MaintenancePump no 1 motor conducors is jammed.so we change it by new one.OtherGRANULATION TANK (FURNACE 2)
1642827 Apr 2020Scheduled MaintenanceALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7 & ALL VIBRATORS
1. checked the motor condition. no noise coming.
2. checked panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. checked limit switches and its condition. it is ok.
OtherRMHS CONVEYOR
1642927 Apr 2020Scheduled MaintenanceALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. greasing of bearings is done.
2. check belt status BC 6 belt condition is not good. we inform it HOD.
3. gearbox oil level checked.
4. check coupling and key it is ok. greasing done.
5. checked the drum condition. its ok.
6. checked the mounting frame welding condition.

OtherRMHS CONVEYOR
1643027 Apr 2020Otherfor Mansa
we check the water pump and start by giving supply from the DG set. its current and voltages also checking. it's working properly.
OtherOTHERS