| 16401 | 30 Apr 2020 | Other | For mansa starter
push button connection Remaking and 3 phase mcb and single phase switch board making is done. | Other | OTHERS | |
| 16402 | 30 Apr 2020 | Breakdown Maintenance | Two cooker stove not working. The cable is short circuit.So we repaired it. Now it is working. | Other | LAB EQUIPMENT | |
| 16403 | 30 Apr 2020 | Breakdown Maintenance | It's pulley damaged so we replace motor and connection given and checked it's working now. | Other | COPPER PLATE CUTTING MACHINE | |
| 16404 | 30 Apr 2020 | Scheduled Maintenance | CHIPPING YARD E.O.T. CRANE 1
LT.
1. checked coupling, shaft, and pedestal bearing condition. The shaft condition is not good.
2. checked the gearbox oil level is good.no leakage.
3. checked all fasteners and mounting bolts.
4. check frame welding conditions.it is ok.
5. check end traveling gears condition. one wheel is not good.
CT.
1. checked CT travel condition is ok.
2. check frame welding conditions. it is ok.
HT.
1. checked rope. it is ok. we change 2 sealing for lifting the metal.
| Other | CHIPPING YARD CRANE NO. 1 | |
| 16405 | 30 Apr 2020 | Scheduled Maintenance | TELPHER FOR F1
1. checking the bearing, rollers condition. it is ok.
2. checking frames welding condition.it is ok.
3. checking cotter pin and its failure condition.it is ok.
| Other | TELPHER (FURNACE 1) | |
| 16406 | 30 Apr 2020 | Scheduled Maintenance | TELPHER FOR F2
1. checking the bearing, rollers condition. it is ok.
2. checking frames welding condition.it is ok.
3. checking cotter pin and its failure condition.it is ok.
| Other | TELPHER ( FURNACE 2) | |
| 16407 | 30 Apr 2020 | Scheduled Maintenance | POLLUTION ID FANS (Furnace 1)
1. check v belts condition. it is ok.
2. check foundation bolts and nuts of Plummer blocks.it is ok and tightened.
| Other | POLLUTION 1 | |
| 16408 | 30 Apr 2020 | Scheduled Maintenance | POLLUTION ID FANS FOR (Furnace 2)
1. check v belts condition. it is ok.
2. check foundation bolts and nuts of Plummer blocks.it is ok and tightened.
| Other | POLLUTION 2 | |
| 16409 | 30 Apr 2020 | Scheduled Maintenance | CHIPPING YARD E.O.T. CRANE 1
LT.
1. check motor condition.
2. checked panel board, clean, & tight all loose parts.
4. check limit switches and its condition.it is ok.
CT.
1. check the motor condition. it is ok.
2.check limit switches and their condition.it is ok.
HT.
1. check the motor condition. it is ok.
| Other | CHIPPING YARD CRANE NO. 1 | |
| 16410 | 30 Apr 2020 | Scheduled Maintenance | TELPHER FOR F1
1.check motor condition. it is ok.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
| Other | TELPHER (FURNACE 1) | |