| 16261 | 13 May 2020 | Breakdown Maintenance | It's battery terminal is broken. So we change it.now it's working. | Other | TATA TIPPER | |
| 16262 | 13 May 2020 | Scheduled Shutdown | It's blower changed. | Furnace I | ELECTRODE 2 | |
| 16263 | 13 May 2020 | Scheduled Shutdown | Its blower changed. | Furnace I | ELECTRODE 2 | |
| 16264 | 13 May 2020 | Scheduled Maintenance | It's ID Fan no. 1 balancing and greasing is done. Now it's have less vibration. | Other | POLLUTION 1, ID FAN NO. 1 | |
| 16265 | 12 May 2020 | Scheduled Maintenance | WATER CIRCULATION PUMP 1,2,3,
FURNACE 1
GRANULATION PUMP 1,2
SUBMERSIBLE PUMP 1,2,
POLLUTION WATER PUMP NO 1
FURNACE 2
GRANULATION PUMP 1,2,
POLLUTION WATER PUMP NO 1,
OFFICE SUBMERSIBLE PUMP 1,
WASHING PLANT SUBMERSIBLE PUMP 1
1. check the pump condition and check discharge.it is ok. We fit f1 pollution pump gland rope and now it is ok.
2. check coupling condition, alignment, and do greasing.it is ok.
3. check pipelines and valve's condition.
4. check cooling towers nozzles condition.it Is ok.
| Other | PUMP | |
| 16266 | 12 May 2020 | Scheduled Maintenance | F1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, SUBMERSIBLE PUMP MOTOR 1,2, POLLUTION WATER PUMP MOTOR
NO 1
F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1, OFFICE SUBMERSIBLE PUMP MOTOR 1,
WASHING PLANT SUBMERSIBLE PUMP MOTOR1
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.checked and it is ok.
2. check panel board, clean, & tight all loose parts.loose parts tight and clean.
3. all parts clean by hand blower.
4. water circulation pump motor greasing. It is OK.we on pump no. 1 and pump no 2 is on standby.
| Other | PUMP | |
| 16267 | 12 May 2020 | Breakdown Shutdown | Its pressure bolt is tight too much. Thats why electrode shlipping problem is coming. So we loose pressure bolts and after that slipping is done easily. | Furnace II | ELECTRODE 1 | |
| 16268 | 12 May 2020 | Breakdown Maintenance | It's starter seal is not good. So starter not working we change it now it's ok. | Other | LODER NO.2 | |
| 16269 | 12 May 2020 | Breakdown Maintenance | It's right centre tyre puncher repairing is done. | Other | TATA TIPPER | |
| 16270 | 12 May 2020 | Breakdown Shutdown | It's clamp no B6 has lekage. So we put pulp but water not coming back at outlet. the pulp stuck into pipe line so we find the place where the pulp is stuck and remove the pulp . Now it's ok.but we need to change the contact clamp. | Furnace I | ELECTRODE 2 | |