| 16211 | 15 May 2020 | Scheduled Maintenance | F1- ELECTRODE BLOWER 3
F1- ELECTRODE BLOWER 1
SEAL COOLING BLOWER 1,
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower. | Furnace I | ELECTRODE 3 | |
| 16212 | 15 May 2020 | Scheduled Maintenance | FURNACE 1
F1- ELECTRODE BLOWER 1
SEAL COOLING BLOWER 1,
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it is ok.
| Furnace I | HYDRAULIC POWER PACK NO. 1 | |
| 16213 | 15 May 2020 | Scheduled Maintenance | FURNACE 1
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it is ok. | Furnace I | HYDRAULIC POWER PACK NO. 2 | |
| 16214 | 15 May 2020 | Scheduled Maintenance | ELECTRODE BLOWER 1
SEAL COOLING BLOWER 1,
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
| Furnace II | ELECTRODE 1 | |
| 16215 | 15 May 2020 | Scheduled Maintenance | ELECTRODE BLOWER 2
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower. | Furnace II | ELECTRODE 2 | |
| 16216 | 15 May 2020 | Scheduled Maintenance | ELECTRODE BLOWER 3
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower. | Furnace II | ELECTRODE 3 | |
| 16217 | 15 May 2020 | Scheduled Maintenance | FURNACE 2
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it is ok. | Furnace II | HYDRAULIC POWER PACK NO. 1 | |
| 16218 | 15 May 2020 | Scheduled Maintenance | FURNACE 2
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it is ok. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 16219 | 15 May 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok. temp. is good.
2. check transformer oil leakage.no leakage.
3. check crystal color.it is ok. | Furnace II | FURNACE 2 TRANSFORMER NO. 1 ( GROUND FLOOR) | |
| 16220 | 15 May 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok. temp. is good.
2. check transformer oil leakage.no leakage.
3. check crystal color.it is ok. | Furnace II | FURNACE 2 TRANSFORMER NO. 2 | |