1607129 May 2020Scheduled Maintenance1. check the water manifold line, T section, and valves. some t section is not good and some dummies also not in good condition.
2. check leakage of hose pipes.it is ok.
Furnace IIWATER MAINEFOLD
1607229 May 2020Scheduled Maintenance1. by air pipe clean dust from all cylinders.
2. no leakage of hydraulic oil
Furnace IELECTRODE 2
1607329 May 2020Scheduled Maintenance1. by air pipe clean dust from all cylinders.
2. no leakage of hydraulic oil
Furnace IELECTRODE 3
1607429 May 2020Scheduled Maintenance1. by air pipe clean dust from all cylinders.
2. no leakage of hydraulic oil
Furnace IELECTRODE 1
1607529 May 2020Breakdown MaintenanceIts 2 nos. Conductor changed.OtherGRANULATION TANK (FURNACE 2)
1607629 May 2020OtherIntercom connection given from time office to maingate.OtherINTERCOM
1607728 May 2020Scheduled MaintenanceCHIPPING YARD E.O.T. CRANE 1

LT.
1. check coupling, shaft, and pedestal bearing condition and do the greasing.checked and greasing is done.
2. check the gearbox oil level, leakage, and fill if required. we found leakage so we fill some amount of grease.
3. check all fasteners and mounting bolts. it is ok.
4. check frame welding conditions. it is not ok. its shaft condition is not good.
5. check end traveling gears condition and do the greasing. it is ok.

CT.
gears are ok. it is good in condition.
HT.
1. check rope drum, hook, rope condition. greasing of rope.rope greasing is done. it is in good condition.
2. check the thruster drum condition and its brake tightness.no thruster.
3. check all fasteners and mounting bolts. it is ok.
4. check frame welding conditions.it is ok.
OtherCHIPPING YARD CRANE NO. 1
1607828 May 2020Scheduled MaintenanceTELPHER FOR F1
1. checking the bearing, rollers condition, and do lubrication.check it is ok.
2. checking frames welding condition.it is ok.
3. checking cotter pin and its failure condition. it is ok.
OtherTELPHER (FURNACE 1)
1607928 May 2020Scheduled MaintenanceTELPHER FOR F2

1. checking the bearing, rollers condition, and do lubrication.check it is ok.
2. checking frames welding condition.it is ok.
3. checking cotter pin and its failure condition. it is ok.
OtherTELPHER ( FURNACE 2)
1608028 May 2020Scheduled MaintenancePOLLUTION ID FANS (Furnace 1)
1. open cover and clean dust.clean and balancing is done.
2. check the balancing of impeller and vibration isolation.it is ok.
3. check v belts condition and inform if it's on critical stage.it is ok.
4. check foundation bolts and nuts of Plummer blocks.it is ok.
5. greasing the Plummer blocks.greasing is done.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature. it is ok.
OtherPOLLUTION 1