| 16061 | 29 May 2020 | Scheduled Maintenance | FURNACE 2
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it is ok. | Furnace II | HYDRAULIC POWER PACK NO. 1 | |
| 16062 | 29 May 2020 | Scheduled Maintenance | FURNACE 2
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tighten loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it is ok. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 16063 | 29 May 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok.
2. check transformer oil leakage.no oil leakage.
3. check crystal color.it is ok. | Furnace II | FURNACE 2 TRANSFORMER NO. 1 ( GROUND FLOOR) | |
| 16064 | 29 May 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok.
2. check transformer oil leakage.no oil leakage.
3. check crystal color.it is ok. | Furnace II | FURNACE 2 TRANSFORMER NO. 2 | |
| 16065 | 29 May 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok.
2. check transformer oil leakage.no oil leakage.
3. check crystal color.it is ok. | Furnace I | FURNACE 1 TRANSFORMER | |
| 16066 | 29 May 2020 | Scheduled Maintenance | 1.check solenoid valve condition and its pipe condition. it is ok. solenoid valves are in good condition.
2.check pneumatic cylinders and air supply lines.it is ok.
3. check charging chute leakage. if it is then inform HOD. it is ok. | Furnace I | CHARGING CHUTES | |
| 16067 | 29 May 2020 | Scheduled Maintenance | 1.check solenoid valve condition and its pipe condition. it is ok. solenoid valves are in good condition.
2.check pneumatic cylinders and air supply lines.it is ok.
3. check charging chute leakage. if it is then inform HOD. it is ok. | Furnace II | CHARGING CHUTES | |
| 16068 | 29 May 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank. IT IS OK.
2. check solenoid valve working conditions and adjust oil pressure. IT IS OK.
3. check hydraulic line leakage. | Furnace I | HYDRAULIC POWER PACK NO. 1 | |
| 16069 | 29 May 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank. IT IS OK.
2. check solenoid valve working conditions and adjust oil pressure. IT IS OK.
3. check hydraulic line leakage. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 16070 | 29 May 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. some t section is not good and some dummies also not in good condition.
2. check leakage of hose pipes.it is ok. | Furnace I | WATER MAINEFOLD | |