Maintenance Report

Search Filter:

Showing 15,901-15,910 of 17,159 items.

#DateTypeDetailsFurnaceEquipmentActions
1590115 Jun 2020Scheduled MaintenanceALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. greasing of bearings. it is done.
2. lubrication of rollers and check conditions. it is ok.
3. check belt status ( if damaged than inform and change) and also check tightness, speed. ALL BELT CONVEYORS CONDITION IS OK EXCEPT BC 2. WE NEED TO CHANGE IT. WE INFORM IT TO HOD.
4. gearbox oil level check and if not then fill as per requirement. ALL GEARBOX ARE OK.we fill grease.
5. check coupling and key ( if damaged than inform and change) and do the greasing. IT IS OK. GREASING IS DONE.
6. check the drum condition. IT IS OK.
7. check mounting frame welding condition. IT IS OK.
8. check rollers condition and if not good then change.
OtherRMHS CONVEYOR
1590213 Jun 2020Otherpollution work is complete.OtherPOLLUTION 1
1590313 Jun 2020Scheduled MaintenanceTILTING HOPPER
1. greasing all bushes.
2.hydraulic pump and motor coupling.
3. checking the hydraulic oil level and if not then fill.
4. check hopper welding section.its ok.

CONVEYOR NO 1
1. greasing of bearings. greasing is done.
2. lubrication of rollers and check conditions.it is ok.
3. check belt status ( if damaged than inform and change) and also check tightness, speed.it is ok.
4. gearbox oil level check and if not then fill as per requirement.it is ok. we fill some grease.
5. check coupling and key ( if damaged than inform and change) and do the greasing.it is ok.
6. check the drum condition.it is ok.
7. check mounting frame welding condition. we weld limit switches supporting frames.
8. check rollers condition and if not good then change.

CRUSHER crusher plate is out due to bolt has broken.
1. check the crusher foundation.
2. check V belts condition.
3. do greasing.
4. check spring rod condition and gap between plates.

VIBRATOR its shaft is broken.
1. check the spring condition.
2. check V belts condition.
3. check vibrations if not good then adjust.
4. check the frame welding condition.

ROLLER
1. check roller speed. it is ok.
2.greasing of bearings. greasing is done.
3.gearbox oil level check and if not then fill as per requirement. it is ok. we fill some grease.
4. check coupling and key ( if damaged than inform and change) and do the greasing. it is ok.
5. check the drum condition.it is ok.
6. check the mounting frame welding condition.

DISCHARGE CONVEYOR
1. greasing of bearings.greasing is done.
2. lubrication of rollers and check conditions. it is ok.
3. check belt status ( if damaged than inform and change) and also check tightness, speed.it is ok.
4. gearbox oil level check and if not then fill as per requirement. we fill grease.
5. check coupling and key ( if damaged than inform and change) and do the greasing. it is ok.
6. check the drum condition.
7. check mounting frame welding condition.
8. check rollers condition and if not good then change.
OtherWASHING PLANT
1590413 Jun 2020Scheduled MaintenanceWASHING PLANT TILTING HOPPER, CONVEYOR NO 1, CRUSHER, VIBRATOR, ROLLER, DISCHARGE CONVEYOR , WATER PUMP


1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. All motors checked .It's in good condition.
2. check panel board, clean, & tight all loose parts.its clean and loose parts tight.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly. It is ok. Mechanical people weld it's foundation.
5. check the high mast lights also.it is ok.
OtherWASHING PLANT
1590513 Jun 2020Otherone cock crusher is ready. we fit 10 hp motor to it.Othercock crusher
1590612 Jun 2020Scheduled MaintenanceF1- ELECTRODE BLOWER 1
SEAL COOLING BLOWER 1,
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tight all loose parts.
3. all parts clean by hand blower.
Furnace IELECTRODE 1
1590712 Jun 2020Scheduled MaintenanceF1- ELECTRODE BLOWER 2

1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tight all loose parts.
3. all parts clean by hand blower.
Furnace IELECTRODE 2
1590812 Jun 2020Scheduled MaintenanceF1- ELECTRODE BLOWER 3

1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tight all loose parts.
3. all parts clean by hand blower.
Furnace IELECTRODE 3
1590912 Jun 2020Scheduled MaintenanceFURNACE 1

1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tight all loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.It is ok.

Furnace IHYDRAULIC POWER PACK NO. 1
1591012 Jun 2020Scheduled MaintenanceFURNACE 1

1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tight all loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.It is ok.
Furnace IHYDRAULIC POWER PACK NO. 2