1586119 Jun 2020Scheduled Maintenance1. checking loose parts and check the hydraulic oil level in the tank.it is ok. no leakage.
2. check solenoid valve working conditions and adjust oil pressure.it is in good condition.
3. check hydraulic line leakage.no leakage.
Furnace IIHYDRAULIC POWER PACK NO. 2
1586219 Jun 2020Scheduled Maintenance1. check the water manifold line, T section, and valves. some t section is not good. and some dummies also not in good condition.
2. check leakage of hose pipes.it is ok.
Furnace IWATER MAINEFOLD
1586319 Jun 2020Scheduled Maintenance1. check the water manifold line, T section, and valves. some t section is not good.
2. check leakage of hose pipes.it is ok.
Furnace IIWATER MAINEFOLD
1586419 Jun 2020Scheduled Maintenance1. by air pipe clean dust from all cylinders.small leakage in the slipping cylinder.
2. check leakage of hydraulic oil. if it is then informed to HOD.
Furnace IELECTRODE 2
1586519 Jun 2020Scheduled Maintenance1. by air pipe clean dust from all cylinders.it is ok. no leakage.
2. check leakage of hydraulic oil. if it is then informed to HOD.
Furnace IELECTRODE 3
1586619 Jun 2020Scheduled Maintenance1. by air pipe clean dust from all cylinders.small leakage in the clamping cylinder.
2. check leakage of hydraulic oil. if it is then informed to HOD.
Furnace IELECTRODE 1
1586719 Jun 2020Breakdown MaintenanceDischarge Vibro feeder no 2 is not working. we check the alignment and fix it. now its working.OtherRMHS VIBRO FEEDER
1586819 Jun 2020Breakdown Maintenanceits impeller unbalanced. we clean and start.OtherPOLLUTION 2, ID FAN NO. 1
1586919 Jun 2020Breakdown Maintenanceits creating vibration so we tight Plummer block foundation bolts and clean impeller. now its workingOtherPOLLUTION 2, ID FAN NO. 1
1587018 Jun 2020Scheduled MaintenanceCHIPPING YARD E.O.T. CRANE 1
LT.
1. check coupling, shaft, and pedestal bearing condition and do the greasing.checked and greasing is done.
2. check the gearbox oil level, leakage, and fill if required. we found leakage so we fill some amount of grease.
3. check all fasteners and mounting bolts. it is ok.
4. check frame welding conditions. it is not ok. its shaft condition is not good.
5. check end traveling gears condition and do the greasing. it is ok.

CT.
gears are ok. it is good in condition.
HT.
1. check rope drum, hook, rope condition. greasing of rope.rope greasing is done. it is in good condition.
2. check the thruster drum condition and its brake tightness.no thruster.
3. check all fasteners and mounting bolts. it is ok.
4. check frame welding conditions.it is ok.
OtherCHIPPING YARD CRANE NO. 1