| 15721 | 03 Jul 2020 | Scheduled Maintenance | FURNACE 2
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts.clean and tight all loose parts.
3. all parts clean by hand blower.
4. check solenoid valves.it's ok. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 15722 | 03 Jul 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok.
2. check transformer oil lekage.no leakage.
3.check crystal colors.it is ok. | Furnace II | FURNACE 2 TRANSFORMER NO. 1 ( GROUND FLOOR) | |
| 15723 | 03 Jul 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok.
2. check transformer oil lekage.no leakage.
3.check crystal colors.it is ok. | Furnace II | FURNACE 2 TRANSFORMER NO. 2 | |
| 15724 | 03 Jul 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it is ok.
2. check transformer oil lekage.no leakage.
3.check crystal colors.it is ok. | Furnace I | FURNACE 1 TRANSFORMER | |
| 15725 | 03 Jul 2020 | Scheduled Maintenance | 1.check solenoid valve condition and its pipe condition. its ok.
2.check pneumatic cylinders and air supply line. its ok.
3. check charging chute lekage. if it is than inform HOD. charging chuts welding is done. | Furnace I | CHARGING CHUTES | |
| 15726 | 03 Jul 2020 | Scheduled Maintenance | 1.check solenoid valve condition and its pipe condition. its ok. no leakage.
2.check pneumatic cylinders and air supply line. it is ok.
3. check charging chute lekage. if it is than inform HOD. | Furnace II | CHARGING CHUTES | |
| 15727 | 03 Jul 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank.it id ok.
2. check solenoid valve working conditions and adjust oil pressure. it is ok.
3. check hydraulic line leakage.no leakage. | Furnace I | HYDRAULIC POWER PACK NO. 1 | |
| 15728 | 03 Jul 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank.hydrauliac oil level is low. we need to fill oil. tomorrow we fill oil in the tank.
2. check solenoid valve working conditions and adjust oil pressure. it is ok.
3. check hydraulic line leakage. it is ok. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 15729 | 03 Jul 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. 5 nos. T section and 2 nos. valves changing is done.
2. check leakage of hose pipes. transformer side 4 nos. hose pipe change. | Furnace I | WATER MAINEFOLD | |
| 15730 | 03 Jul 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. it is ok.
2. check leakage of hose pipes. it is ok. | Furnace II | WATER MAINEFOLD | |