| 15641 | 13 Jul 2020 | Breakdown Maintenance | It's front light bulb changing is done. | Other | LODER NO. 9 | |
| 15642 | 13 Jul 2020 | Breakdown Maintenance | Brake hose nipple changing is done. Now it's ok. | Other | ESCORT HYDRA | |
| 15643 | 13 Jul 2020 | Scheduled Maintenance | ALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. it's ok.
2. check panel board, clean, & tight all loose parts. clean and tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly. its ok.
| Other | RMHS CONVEYOR | |
| 15644 | 13 Jul 2020 | Scheduled Maintenance | ALL VIBRATORS
check Vibro feeders coil connection, its condition and ensure its working properly with adjusting its vibrations. its ok. | Other | RMHS VIBRO FEEDER | |
| 15645 | 13 Jul 2020 | Scheduled Maintenance | ALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. greasing of bearings. greasing is done.
2. lubrication of rollers and check conditions. we fix BC 6 and BC 1 rollers.
3. check belt status ( if damaged than inform and change) and also check tightness, speed. it's ok. we tight BC 6 belt and fix fasteners.
4. gearbox oil level check and if not then fill as per requirement. BC 7 has leakage. we fill grease.
5. check coupling and key ( if damaged than inform and change) and do the greasing.it's ok. we need to change BC 6 coupling. its making work is in progress.
6. check the drum condition. it's ok.
7. check mounting frame welding condition. we weld BC 7 and BC 6 side holes.
8. check rollers condition and if not good then change.
| Other | RMHS CONVEYOR | |
| 15646 | 12 Jul 2020 | Breakdown Maintenance | Pollution gate is filled with dust and mud. We clean it and open. | Other | POLLUTION 1 | |
| 15647 | 11 Jul 2020 | Breakdown Maintenance | H.T.
its coil is burning. we send motor for rewinding.
REWINDING IS DONE. ITS HANDOVER TO MECHANICAL DEPT. FOR FITTING ON CRANE. | Other | TAPPING SEC. CRANE NO. 2 | |
| 15648 | 11 Jul 2020 | Breakdown Maintenance | It's brake cylinder hose pipe is broken. We fitting new one. | Other | ESCORT HYDRA | |
| 15649 | 11 Jul 2020 | Breakdown Maintenance |
Engine maintenance with 18 ltr. Oil.
2 nos. Primary and secondary Engine oil filter .
And 2 nos. Primary and secondary diesel filter changed. | Other | LODER NO.2 | |
| 15650 | 11 Jul 2020 | Scheduled Maintenance | 1.check transformer temp. and oil level.it's ok.
2. check transformer oil leakage.its ok.
3.check crystal colors.it's ok. | Furnace I | FURNACE 1 TRANSFORMER | |