| # | Date | Type | Details | Furnace | Equipment | Actions |
|---|---|---|---|---|---|---|
| 15631 | 15 Jul 2020 | Scheduled Maintenance | TAPPING SECTION E.O.T. CRANE 1 LT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. CT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. HT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. | Other | TAPPING SEC. CRANE NO. 1 | |
| 15632 | 15 Jul 2020 | Scheduled Maintenance | TAPPING SECTION E.O.T. CRANE 2 LT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. CT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. HT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. | Other | TAPPING SEC. CRANE NO. 2 | |
| 15633 | 15 Jul 2020 | Scheduled Maintenance | TAPPING SECTION E.O.T. CRANE 3 LT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. CT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. HT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok. 2. check panel board, clean, & tight all loose parts. clean and tight loose parts. 3. all parts clean by hand blower. 4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly. | Other | TAPPING SEC. CRANE NO. 3 | |
| 15634 | 15 Jul 2020 | Scheduled Maintenance | 3RD FLOOR CARBON PASTE LIFTING CRANE LT., CT. , HT. 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok. 2. check panel board, clean, & tight all loose parts. Clean and tighten all loose parts. 3. all parts clean by hand blower. 4. No limit switches. | Other | CARBON PASTE LIFTING CRANE | |
| 15635 | 14 Jul 2020 | Breakdown Maintenance | Pollution id fan has vibration. We clean it and tight bolts . Now it's ok. | Other | POLLUTION 2, ID FAN NO. 2 | |
| 15636 | 14 Jul 2020 | Scheduled Maintenance | WATER CIRCULATION PUMP 1,2,3, we greasing pump no. 2 its ready and is in standby. FURNACE 1 GRANULATION PUMP 1,2 it's ok. we greasing coupling. SUBMERSIBLE PUMP 1,2, POLLUTION WATER PUMP NO 1 It has heavy leakage. we fix it with gland rope. but still leakage. we need new monoblock. FURNACE 2 GRANULATION PUMP 1,2, pump no. 1 coupling bolt is loosed. we replace it with gear coupling. POLLUTION WATER PUMP NO 1, its has leakage. we fix the leakage. OFFICE SUBMERSIBLE PUMP 1, WASHING PLANT SUBMERSIBLE PUMP 1 1. check the pump condition and check discharge. 2. check coupling condition, alignment, and do greasing. 3. check pipelines and valve's condition. 4. check cooling towers nozzles condition. its condition is ok. | Other | PUMP | |
| 15637 | 14 Jul 2020 | Scheduled Maintenance | F1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, SUBMERSIBLE PUMP MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1 F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1, OFFICE SUBMERSIBLE PUMP MOTOR 1, WASHING PLANT SUBMERSIBLE PUMP MOTOR1 1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.checked and clean. 2. check panel board, clean, & tight all loose parts.clean,tight all loose parts. 3. all parts clean by hand blower. 4. water circulation pump motor greasing. It's ok. We was greased it last time. 5. We need to change both pollution pumps because of leakage. | Other | PUMP | |
| 15638 | 14 Jul 2020 | Breakdown Maintenance | pump no. 2 its Oldham coupling nut bolts are loose. because Oldham coupling does not work at high speed. when we doing scheduled maintenance. we changed replace it with gear coupling. | Other | GRANULATION TANK (FURNACE 2) | |
| 15639 | 13 Jul 2020 | Breakdown Maintenance | It's contact clamp no. A4 is leakage. We fill pulp now it's ok. | Furnace II | ELECTRODE 1 | |
| 15640 | 13 Jul 2020 | Scheduled Shutdown | When we check daily basis. We found that it's not have hydraulic oil. So we fill 30 ltr. Oil. | Other | JCB 4DX | |