Maintenance Report

Search Filter:

Showing 15,451-15,460 of 17,159 items.

#DateTypeDetailsFurnaceEquipmentActions
1545106 Aug 2020Scheduled MaintenanceTELPHER FOR F2

1. checking the bearing, rollers condition, and do lubrication.check it is ok.
2. checking frames welding condition.it is ok.
3. checking cotter pin and its failure condition. it is ok.


OtherTELPHER ( FURNACE 2)
1545206 Aug 2020Scheduled MaintenancePOLLUTION ID FANS (Furnace 1)
1. open cover and clean dust.clean and balancing is done. tight nut bolts.
2. check the balancing of impeller and vibration isolation.it is ok.
3. check v belts condition and inform if it's on critical stage.it is ok.
4. check foundation bolts and nuts of Plummer blocks.it is ok.
5. greasing the Plummer blocks.greasing is done.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature. it is ok.
OtherPOLLUTION 1
1545306 Aug 2020Scheduled MaintenancePOLLUTION ID FANS FOR (Furnace 2)
1. open cover and clean dust.clean and balancing is done. tight nut bolts.
2. check the balancing of impeller and vibration isolation.it is ok.
3. check v belts condition and inform if it's on critical stage.it is ok.
4. check foundation bolts and nuts of Plummer blocks.it is ok.
5. greasing the Plummer blocks.greasing is done.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature. it is ok.
OtherPOLLUTION 2
1545406 Aug 2020Scheduled MaintenanceCHIPPING YARD E.O.T. CRANE 1

LT.
1. check motor condition.
2. checked panel board, clean, & tight all loose parts.
4. check limit switches and its condition.it is ok.

CT.
1. check the motor condition. it is ok.
2.check limit switches and their condition.it is ok.

HT.
1. check the motor condition. it is ok.
OtherCHIPPING YARD CRANE NO. 1
1545506 Aug 2020Scheduled MaintenanceCHIPPING YARD E.O.T. CRANE 2

bus bar line is ok.
LT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly.

CT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly.

HT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.it is ok. working properly.
OtherCHIPPING YARD CRANE NO. 2
1545606 Aug 2020Scheduled MaintenanceTELPHER FOR F1
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform. motor condition checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight all loose parts.
3. all parts clean by hand blower.
OtherTELPHER (FURNACE 1)
1545706 Aug 2020Scheduled MaintenanceTELPHER FOR F2
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform. motor condition checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight all loose parts.
3. all parts clean by hand blower.
OtherTELPHER ( FURNACE 2)
1545806 Aug 2020Scheduled MaintenancePOLLUTION ID FANS FOR F1
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform. motor condition checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight all loose parts.
3. all parts clean by hand blower.
4. MOTOR GREASING.
OtherPOLLUTION 1
1545906 Aug 2020Scheduled MaintenancePOLLUTION ID FANS FOR F2
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform. motor condition checked. it is ok.
2. check panel board, clean, & tight all loose parts. clean and tight all loose parts.
3. all parts clean by hand blower.
4. MOTOR GREASING.
OtherPOLLUTION 2
1546005 Aug 2020Scheduled MaintenanceTAPPING SECTION E.O.T. CRANE 1

LT.
1. check coupling, shaft, and pedestal bearing condition and do the greasing. check bearing condition it is ok. And greasing is done.
2. check the gearbox oil level, leakage, and fill if required. No leakage we fill some grease.
3. check all fasteners and mounting bolts.it is ok.
4. check frame welding conditions. It is ok.
5. check end traveling gears condition and do the greasing. It is ok.greasing is done.

CT.
1. check coupling, shaft, and pedestal bearing condition and do the greasing. Greasing is done.
2. check the gearbox oil level, leakage, and fill if required. It has leakage but we fill some grease.
3. check all fasteners and mounting bolts.it is ok.
4. check frame welding conditions. It is ok.
5. check end traveling gears condition and do the greasing. It is ok.
6. we fit 2 nos. bolts on the coupling side.
HT.
1. check rope drum, hook, rope condition. greasing of rope. It is ok. Greasing is done.
2. check all fasteners and mounting bolts. It is ok.
3. check frame welding conditions. It is ok.
4. gearbox oil level is ok.
OtherTAPPING SEC. CRANE NO. 1