#DateTypeDetailsFurnaceEquipmentActions
1529126 Aug 2020Scheduled Maintenance3RD FLOOR CARBON PASTE LIFTING CRANE

LT., CT. , HT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.it is ok.
2. check panel board, clean, & tight all loose parts. Clean and tighten all loose parts.
3. all parts clean by hand blower.
4. No limit switches.
OtherCARBON PASTE LIFTING CRANE
1529225 Aug 2020Scheduled MaintenanceWATER CIRCULATION PUMP 1,2,3,
pump no. 2 is ready.
FURNACE 1
GRANULATION
SUBMERSIBLE PUMP 1,2, PUMP 1,2
it's ok.
POLLUTION WATER PUMP NO 1
It has heavy leakage. we fix it with gland rope. but still leakage. we need new monoblock.
FURNACE 2
GRANULATION PUMP 1,2,
The greasing of coupling is done.

POLLUTION WATER PUMP NO 1, NO.2
it has leakage. we fix the leakage. now it's ok.
NO.2 pump welding side M-seal fitting is done. we fix gland ropes leakage. we fix air leakage also.
OFFICE SUBMERSIBLE PUMP 1,
WASHING PLANT SUBMERSIBLE PUMP 1
washing plant side pump is ok.

1. check the pump condition and check discharge.
2. check coupling condition, alignment, and do greasing.
3. check pipelines and valve's condition.
4. check cooling towers nozzles condition. its condition is ok.
OtherPUMP
1529325 Aug 2020Scheduled MaintenanceF1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, SUBMERSIBLE PUMP MOTOR 1,2, POLLUTION WATER PUMP MOTOR
NO 1

F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1, OFFICE SUBMERSIBLE PUMP MOTOR 1,
WASHING PLANT SUBMERSIBLE PUMP MOTOR1


1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.check and clean. All loose bolts and nuts tight.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. water circulation pump motor greasing. It is ok.
OtherPUMP
1529425 Aug 2020Scheduled MaintenanceThe 3rd-floor side camera fitting is done.OtherCAMERA
1529524 Aug 2020Scheduled MaintenanceALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform. it's ok.
2. check panel board, clean, & tight all loose parts. clean and tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly. its ok.
OtherRMHS CONVEYOR
1529624 Aug 2020Scheduled MaintenanceALL VIBRATORS
check Vibro feeders coil connection, its condition and ensure its working properly with adjusting its vibrations. BC 1 and BC 3 sides all Vibro feeders not in good condition.
OtherRMHS VIBRO FEEDER
1529724 Aug 2020Scheduled MaintenanceALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. greasing of bearings.greasing is done.
2. lubrication of rollers and check conditions.its ok.
3. check belt status ( if damaged than inform and change) and also check tightness, speed. BC 6 and BC 7 are not in good condition we fitting fasteners and we fit separators for removing big stones from the drum.
4. gearbox oil level check and if not then fill as per requirement.it's ok.
5. check coupling and key ( if damaged than inform and change) and do the greasing.it's ok. BC 2 side coupling is not in good condition. we change it this week.
6. check the drum condition. it's ok.
7. check mounting frame welding condition.it's ok.
8. check rollers condition and if not good then change. we changer BC 6 side one return roller fall down we repaired it.
OtherRMHS CONVEYOR
1529824 Aug 2020Scheduled Maintenance22 kW submersible pump motor testing with a transformer.OtherSUBMERSIBLE PUMP
1529924 Aug 2020Scheduled Maintenanceits pollution venturi side another pipeline giving and one 10 hp motor pump set fitting is done.OtherPOLLUTION 2
1530024 Aug 2020Scheduled Maintenance2 starter and motor connection giving at the pollution side.OtherPOLLUTION 2