| 15261 | 28 Aug 2020 | Scheduled Maintenance | 1.check solenoid valve condition and its pipe condition. it is ok. solenoid valves are in good condition.
2.check pneumatic cylinders and air supply lines.it is ok.
3. check charging chute leakage. if it is then inform HOD. no hole no leakage. | Furnace I | CHARGING CHUTES | |
| 15262 | 28 Aug 2020 | Scheduled Maintenance | 1.check solenoid valve condition and its pipe condition.
2.check pneumatic cylinders and air supply lines.
3. check to charge chute leakage. if it is then inform HOD.
one charging chute gate is damaged. we repaired it. | Furnace II | CHARGING CHUTES | |
| 15263 | 28 Aug 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank.its ok.
2. check solenoid valve working conditions and adjust oil pressure.solenoid is ok.
3. check hydraulic line leakage. | Furnace I | HYDRAULIC POWER PACK NO. 1 | |
| 15264 | 28 Aug 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank.it's ok.
2. check solenoid valve working conditions and adjust oil pressure.solenoid is ok.
3. check hydraulic line leakage.
one pipe of electrode 2 is leakage. we change it in the next shutdown. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 15265 | 28 Aug 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. some t section is not good. and some dummies also not in good condition.
2. check leakage of hose pipes.it is ok. | Furnace I | WATER MAINEFOLD | |
| 15266 | 28 Aug 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. some t section is not good. and some dummies also not in good condition.2 valve are damaged.
2. check leakage of hose pipes.it is ok. | Furnace II | WATER MAINEFOLD | |
| 15267 | 28 Aug 2020 | Scheduled Maintenance | 1. by air pipe clean dust from all cylinders.
2. check leakage of hydraulic oil. if it is then informed to HOD.
no leakage but seal ide small amount of fire coming from the downside. | Furnace I | ELECTRODE 2 | |
| 15268 | 28 Aug 2020 | Scheduled Maintenance | 1. by air pipe clean dust from all cylinders.
2. check leakage of hydraulic oil. if it is then informed to HOD.no oil leakage. but seal side fire is coming from the downside. tomorrow we fix it. | Furnace I | ELECTRODE 3 | |
| 15269 | 28 Aug 2020 | Scheduled Maintenance | 1. by air pipe clean dust from all cylinders.
2. check leakage of hydraulic oil. if it is then informed to HOD.no leakage. | Furnace I | ELECTRODE 1 | |
| 15270 | 28 Aug 2020 | Breakdown Maintenance | discharge vibro feeder no.3 coil side plate broken it was welding making and refitted now working. | Other | RMHS VIBRO FEEDER | |