| 15031 | 23 Sep 2020 | Scheduled Maintenance | 3RD FLOOR CARBON PASTE LIFTING CRANE
LT, C.T, AND H.T.
1. checked the motor condition ( amp, volt, and connectivity). no noise coming. it is ok.
2. checked panel board, clean, & tight all loose parts.
3. all parts clean by hand blower. | Other | CARBON PASTE LIFTING CRANE | |
| 15032 | 23 Sep 2020 | Scheduled Maintenance | its shaft is damaged. wae open tire and weld it now it's ok. | Other | WASHING ROLLER ( WASHING PLANT) | |
| 15033 | 23 Sep 2020 | Scheduled Maintenance | LIMIT SWITCH FIXING WITH CABLE . | Other | CRUSHER CONVEYOR | |
| 15034 | 22 Sep 2020 | Scheduled Maintenance | WATER CIRCULATION PUMP 1,2,3,
pump no. 2 is ready.
FURNACE 1
GRANULATION
SUBMERSIBLE PUMP 1,2, PUMP 1,2
we fix the lekage by moutnitg new gland rope and vibration problem. now its ok.
POLLUTION WATER PUMP NO 1
It has heavy leakage. we fix it with gland rope. but still leakage. we need new monoblock.
FURNACE 2
GRANULATION PUMP 1,2,
The greasing of coupling is done.
POLLUTION WATER PUMP NO 1,
it has leakage. we fix the leakage. now it's ok.
OFFICE SUBMERSIBLE PUMP 1,
WASHING PLANT SUBMERSIBLE PUMP 1
washing plant side pump is ok.
1. check the pump condition and check discharge.
2. check coupling condition, alignment, and do greasing.
3. check pipelines and valve's condition.
4. check cooling towers nozzles condition. its condition is ok. | Other | PUMP | |
| 15035 | 22 Sep 2020 | Scheduled Maintenance | F1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, SUBMERSIBLE PUMP MOTOR 1,2, POLLUTION WATER PUMP MOTOR
NO 1
F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1, OFFICE SUBMERSIBLE PUMP MOTOR 1,
WASHING PLANT SUBMERSIBLE PUMP MOTOR1
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.check and clean. All loose bolts and nuts tight.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. water circulation pump motor greasing. It is ok. | Other | PUMP | |
| 15036 | 22 Sep 2020 | Scheduled Maintenance | yesterday we found that BC 6 belt is damaged. we change it today. now its working normal.
| Other | RMHS BELT CONVEYOR NO.6 | |
| 15037 | 22 Sep 2020 | Scheduled Shutdown | C1 clamp is lekaged. we change it. now its ok. | Furnace II | ELECTRODE 3 | |
| 15038 | 22 Sep 2020 | Breakdown Shutdown | its C3 clamp has water leakge. we change it and B5 clamp tie rod welding is done. | Furnace II | ELECTRODE 3 | |
| 15039 | 22 Sep 2020 | Scheduled Maintenance | its belt changed now its ok. | Other | RMHS BELT CONVEYOR NO.6 | |
| 15040 | 22 Sep 2020 | Scheduled Maintenance | GUEST HOUSE SIDE
2 ROOMS WIRING AND 2 FAN FIXING WITH 4 LED LIGHTS. | Other | GUEST HOUSE | |