Maintenance Report

Search Filter:

Showing 14,881-14,890 of 17,159 items.

#DateTypeDetailsFurnaceEquipmentActions
1488107 Oct 2020Scheduled Maintenanceits testing is done. it's ok now.OtherCHIPPING YARD CRANE NO. 2
1488206 Oct 2020Scheduled Maintenanceno maintenance because of furnace and compressor testing side working.

WATER CIRCULATION PUMP 1,2,3,
FURNACE 1
GRANULATION PUMP 1,2
SUBMERSIBLE PUMP 1,2,
POLLUTION WATER PUMP NO 1

FURNACE 2
GRANULATION PUMP 1,2,
POLLUTION WATER PUMP NO 1,
OFFICE SUBMERSIBLE PUMP 1,
WASHING PLANT SUBMERSIBLE PUMP 1

1. check the pump condition and check discharge.
2. check coupling condition, alignment, and do greasing.
3. check pipelines and valve's condition.
4. check cooling towers nozzles condition.
OtherPUMP
1488306 Oct 2020Scheduled Maintenanceworkshop and washing plant compressor testing is done. now its ok.OtherCOMPRESSOR
1488405 Oct 2020Scheduled Maintenancenot done because of furnace is shutdown.
ALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.

OtherRMHS CONVEYOR
1488505 Oct 2020Scheduled MaintenanceNot done because we working finance side.
ALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.

OtherRMHS CONVEYOR
1488605 Oct 2020Scheduled MaintenanceNot done because we working furnace side
ALL VIBRATORS
check Vibro feeders coil connection, its condition and ensure its working properly with adjusting its vibrations.
OtherRMHS VIBRO FEEDER
1488705 Oct 2020Scheduled MaintenanceALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. greasing of bearings.grease already there.
2. lubrication of rollers and check conditions.
3. check belt status ( if damaged than inform and change) and also check tightness, speed.belt is ok.
4. gearbox oil level check and if not then fill as per requirement.
5. check coupling and key ( if damaged than inform and change) and do the greasing.BC 5 key is damaged. We repairing it tomorrow.
6. check the drum condition.BC 7 belt drum changed.
7. check mounting frame welding condition.
8. check rollers condition and if not good then change.
OtherRMHS CONVEYOR
1488805 Oct 2020Breakdown Maintenancenot done. due to furnace side working.

F1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, SUBMERSIBLE PUMP MOTOR 1,2, POLLUTION WATER PUMP MOTOR
NO 1

F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1, OFFICE SUBMERSIBLE PUMP MOTOR 1,
WASHING PLANT SUBMERSIBLE PUMP MOTOR1

1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. water circulation pump motor greasing.
OtherPUMP
1488905 Oct 2020Breakdown MaintenanceBig gurinder not working. Open and carbon brush changed.OtherBIG HAND GRINDER
1489005 Oct 2020Breakdown MaintenanceBig grinder not working. Open and carbon brush changed.OtherBIG HAND GRINDER