Maintenance Report

Search Filter:

Showing 14,561-14,570 of 17,159 items.

#DateTypeDetailsFurnaceEquipmentActions
1456112 Nov 2020Scheduled MaintenanceTELPHER FOR F1
1. checking the bearing, rollers condition, and do lubrication. ITS OK.
2. checking frames welding condition.
3. checking the cotter pin and its failure condition.

OtherTELPHER (FURNACE 1)
1456212 Nov 2020Scheduled MaintenanceTELPHER FOR F2
WE CHANGE TELPHER MOTOR WITH FRAME.
1. checking the bearing, rollers condition, and do lubrication.
2. checking frames welding condition.
3. checking cotter pin and its failure condition.

OtherTELPHER ( FURNACE 2)
1456312 Nov 2020Scheduled MaintenancePOLLUTION ID FANS (Furnace 1) CLEAN AND RUNNING NORMALY.
1. open cover and clean dust.
2. check the balancing of impeller and vibration isolation.
3. check v belts condition and inform if its on critical stage.
4. check foundation bolts and nuts of Plummer blocks.
5. greasing the Plummer blocks.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature.
OtherPOLLUTION 1
1456412 Nov 2020Scheduled MaintenancePOLLUTION ID FANS FOR (Furnace 2) ITS RUNNING NORLMALY.
1. open cover and clean dust.
2. check the balancing of impeller and vibration isolation.
3. check v belts condition and inform if its on critical stage.
4. check foundation bolts and nuts of Plummer blocks.
5. greasing the Plummer blocks.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature.
OtherPOLLUTION 2
1456512 Nov 2020Scheduled MaintenanceCHIPPING YARD E.O.T. CRANE 1

LT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.

CT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.

HT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
OtherCHIPPING YARD CRANE NO. 1
1456612 Nov 2020Scheduled MaintenanceCHIPPING YARD E.O.T. CRANE 2

LT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.

CT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.

HT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
OtherCHIPPING YARD CRANE NO. 2
1456712 Nov 2020Scheduled MaintenanceTELPHER FOR F1
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
OtherTELPHER (FURNACE 1)
1456812 Nov 2020Scheduled MaintenanceTELPHER FOR F2
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
OtherTELPHER ( FURNACE 2)
1456912 Nov 2020Scheduled MaintenancePOLLUTION ID FANS FOR F1
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. MOTOR GREASING.
OtherPOLLUTION 1
1457012 Nov 2020Scheduled MaintenancePOLLUTION ID FANS FOR F2
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. MOTOR GREASING.
OtherPOLLUTION 2