| 14371 | 04 Dec 2020 | Scheduled Maintenance | 1. checking loose parts and check the hydraulic oil level in the tank. no lekage. 2. check solenoid valve working conditions and adjust oil pressure. we fill oil next time. 3. check hydraulic line leakage. | Furnace II | HYDRAULIC POWER PACK NO. 2 | |
| 14372 | 04 Dec 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. its ok. 2. check leakage of hose pipes. | Furnace I | WATER MAINEFOLD | |
| 14373 | 04 Dec 2020 | Scheduled Maintenance | 1. check the water manifold line, T section, and valves. aits ok. 2. check leakage of hose pipes. | Furnace II | WATER MAINEFOLD | |
| 14374 | 04 Dec 2020 | Scheduled Maintenance | 1. by air pipe clean dust from all cylinders. small leakage in electrode hydrdulic. 2. check leakage of hydraulic oil. if it is then informed to HOD. | Furnace I | ELECTRODE 2 | |
| 14375 | 03 Dec 2020 | Scheduled Maintenance | CHIPPING YARD E.O.T. CRANE 1 LT. 1. check coupling, shaft, and pedestal bearing condition and do the greasing.checked and greasing is done. 2. check the gearbox oil level, leakage, and fill if required. we found leakage so we fill some amount of grease. 3. check all fasteners and mounting bolts. it is ok. 4. check frame welding conditions. it is not ok. its shaft condition is not good. we need to change it. 5. check end traveling gears condition and do the greasing. it is ok. CT. gears are ok. it is good in condition. HT. 1. check rope drum, hook, rope condition. greasing of rope. rope greasing is done. it is in good condition. 2. check the thruster drum condition and its brake tightness.no thruster. 3. check all fasteners and mounting bolts. it is ok. 4. check frame welding conditions.it is ok. | Other | CHIPPING YARD CRANE NO. 1 | |
| 14376 | 03 Dec 2020 | Scheduled Maintenance | CHIPPING YARD E.O.T. CRANE 2 LT. 1. check coupling, shaft, and pedestal bearing condition and do the greasing. greasing is done. it is ok. 2. check the gearbox oil level, leakage, and fill if required. no leakage but we fill grease. 3. check all fasteners and mounting bolts. it is ok. 4. check frame welding conditions. it is ok. 5. check end traveling gears condition and do the greasing. CT. 1. check coupling, shaft, and pedestal bearing condition and do the greasing. greasing is done. it is ok. 2. check the gearbox oil level, leakage, and fill if required. no leakage but we fill grease. 3. check all fasteners and mounting bolts. it is ok. 4. check frame welding conditions. it is ok. 5. check end traveling gears condition and do the greasing.it is ok. greasing is done. HT. 1. check rope drum, hook, rope condition. greasing of rope. greasing is done. we found that it is damage. we open and repaired. 2. check the thruster drum condition and its brake tightness. no thruster. 3. check all fasteners and mounting bolts. It is ok. 4. check frame welding conditions.it is ok. | Other | CHIPPING YARD CRANE NO. 2 | |
| 14377 | 03 Dec 2020 | Scheduled Maintenance | TELPHER FOR F1 1. checking the bearing, rollers condition, and do lubrication. ITS OK. 2. checking frames welding condition. 3. checking the cotter pin and its failure condition. | Other | TELPHER (FURNACE 1) | |
| 14378 | 03 Dec 2020 | Scheduled Maintenance | TELPHER FOR F2 1. checking the bearing, rollers condition, and do lubrication. ITS OK. 2. checking frames welding condition. 3. checking the cotter pin and its failure condition. | Other | TELPHER ( FURNACE 2) | |
| 14379 | 03 Dec 2020 | Scheduled Maintenance | POLLUTION ID FANS (Furnace 1) 1. open cover and clean dust.dust clean. 2. check the balancing of impeller and vibration isolation. we repaired it. 3. check v belts condition and inform if its on critical stage. 4. check foundation bolts and nuts of Plummer blocks. 5. greasing the Plummer blocks. greasing is done. 6. check the duct condition and remove dust from the duct. 7. check stack condition and check its temperature. | Other | POLLUTION 1 | |
| 14380 | 03 Dec 2020 | Scheduled Maintenance | pollution is not running. we greasing the bearing. POLLUTION ID FANS FOR (Furnace 2) 1. open cover and clean dust. 2. check the balancing of impeller and vibration isolation. 3. check v belts condition and inform if its on critical stage. 4. check foundation bolts and nuts of Plummer blocks. 5. greasing the Plummer blocks. 6. check the duct condition and remove dust from the duct. 7. check stack condition and check its temperature. | Other | POLLUTION 2 | |