| 13871 | 02 Feb 2021 | Breakdown Maintenance | It's water pump motor is burned. We remove it and giving to rewinding.
We fitting another one motor pump. Now it's running. | Other | WATER PUMP (WASHING PLANT) | |
| 13872 | 02 Feb 2021 | Scheduled Maintenance | WATER CIRCULATION PUMP 1,2,3,
FURNACE 1
GRANULATION PUMP 1,2
SUBMERSIBLE PUMP 1,2,
POLLUTION WATER PUMP NO 1
FURNACE 2
GRANULATION PUMP 1,2,
POLLUTION WATER PUMP NO 1,
OFFICE SUBMERSIBLE PUMP 1,
WASHING PLANT SUBMERSIBLE PUMP 1
1. check the pump condition and check discharge.
2. check coupling condition, alignment, and do greasing.
3. check pipelines and valve's condition.
4. check cooling towers nozzles condition.its ok.
| Other | PUMP | |
| 13873 | 02 Feb 2021 | Scheduled Maintenance | F1- GRANULATION MOTOR 1,2 WATER CIRCULATION PUMP MOTOR 1,2,3, SUBMERSIBLE PUMP MOTOR 1,2, POLLUTION WATER PUMP MOTOR
NO 1
F2- GRANULATION MOTOR 1,2, POLLUTION WATER PUMP MOTOR NO 1, OFFICE SUBMERSIBLE PUMP MOTOR 1,
WASHING PLANT SUBMERSIBLE PUMP MOTOR1
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. water circulation pump motor greasing.
| Other | PUMP | |
| 13874 | 02 Feb 2021 | Breakdown Maintenance | It's belt conveyor is damaged. We repair it. Now it's ok. | Other | RMHS BELT CONVEYOR NO.1 | |
| 13875 | 02 Feb 2021 | Breakdown Maintenance | Pump no 3
It's water pipe line is blocked. We open it and see that it's inside mash is fully damaged we repaired it. Now it's ok. | Other | COOLING TOWER | |
| 13876 | 02 Feb 2021 | Breakdown Shutdown | Its c1 clamp has leakage. We filling pulp to stop it. The pulp is stuck in pipe line and putle water is not coming. So we switch off furnace and open pipe line from top of transformer. Than we open water. So the pulp is coming out. Than we switch on furnace. | Furnace II | FURNACE 2 | |
| 13877 | 01 Feb 2021 | Scheduled Maintenance | ALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
| Other | RMHS CONVEYOR | |
| 13878 | 01 Feb 2021 | Scheduled Maintenance | ALL VIBRATORS
check Vibro feeders coil connection, its condition and ensure its working properly with adjusting its vibrations. | Other | RMHS VIBRO FEEDER | |
| 13879 | 01 Feb 2021 | Scheduled Maintenance | ALL CONVEYORS
BC 1, BC 2, BC 3, BC 4, BC 5, BC 6, BC 7
1. greasing of bearings.
2. lubrication of rollers and check conditions.
3. check belt status ( if damaged than inform and change) and also check tightness, speed.
4. gearbox oil level check and if not then fill as per requirement.
5. check coupling and key ( if damaged than inform and change) and do the greasing.
6. check the drum condition.
7. check mounting frame welding condition.
8. check rollers condition and if not good then change.
| Other | RMHS CONVEYOR | |
| 13880 | 01 Feb 2021 | Breakdown Shutdown | It's c2 and B5 contact clamps are have heavy leakage. We change it. Also we fit 2 tie rods for the same.
We also fit 3 mm sheet for the protection shield. | Furnace II | FURNACE 2 | |