| 11131 | 27 Jan 2022 | Scheduled Maintenance | POLLUTION ID FANS FOR (Furnace 2)
1. open cover and clean dust.
2. check the balancing of impeller and vibration isolation.
3. check v belts condition and inform if its on critical stage.
4. check foundation bolts and nuts of Plummer blocks.
5. greasing the Plummer blocks.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature.
| Other | POLLUTION 2 | |
| 11132 | 27 Jan 2022 | Scheduled Maintenance | CHIPPING YARD E.O.T. CRANE 1
LT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
CT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
HT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
| Other | CHIPPING YARD CRANE NO. 1 | |
| 11133 | 27 Jan 2022 | Scheduled Maintenance | CHIPPING YARD E.O.T. CRANE 2
LT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
CT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
HT.
1. check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. check limit switches and its condition. ensure that all limit switches and wires working properly.
| Other | CHIPPING YARD CRANE NO. 2 | |
| 11134 | 27 Jan 2022 | Scheduled Maintenance | TELPHER FOR F1
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
| Other | TELPHER (FURNACE 1) | |
| 11135 | 27 Jan 2022 | Scheduled Maintenance | TELPHER FOR F2
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
| Other | TELPHER ( FURNACE 2) | |
| 11136 | 27 Jan 2022 | Scheduled Maintenance | POLLUTION ID FANS FOR F1
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. MOTOR GREASING.
| Other | POLLUTION 1 | |
| 11137 | 27 Jan 2022 | Scheduled Maintenance | POLLUTION ID FANS FOR F2
1.check motor condition ( amp, volt, and connectivity) if the noise coming than inform.
2. check panel board, clean, & tight all loose parts.
3. all parts clean by hand blower.
4. MOTOR GREASING.
| Other | POLLUTION 2 | |
| 11138 | 27 Jan 2022 | Breakdown Shutdown | It's clamp number A3 coming down due to bolt damage. We change suspension luck and lower fork. Now it's ok | Furnace II | ELECTRODE 1 | |
| 11139 | 27 Jan 2022 | Breakdown Maintenance | control room inform that operator see sparking at top of center star hood at2nd floor.
when i am going to check it i also saw sparking there but i cant see it properly because to dust.
after that i am checked the casing at 3rd floor that its touching somewhere. but its not. in next shutdown I will check it.
may be its from holding of star hood insulation. | Furnace I | HOOD SECTION | |
| 11140 | 27 Jan 2022 | Other | we are arranging one pump and motor for pollution f1 to supply recycle water inside the container . its work in is progress. | Furnace I | POLLUTION 1 | |