Maintenance Details


Date21 May 2020
Start Time13:30:01
End Time14:30:01
Nature Of MaintenanceMechanical
EquipmentPOLLUTION 1
Type of MaintenanceScheduled Maintenance
DetailsPOLLUTION ID FANS (Furnace 1)
1. open cover and clean dust.
2. check the balancing of impeller and vibration isolation. IT IS OK. WE TIGHTS NUTS AND BOLTS OF PLUMMER BLOCKS. It's MAKING SOME VIBRATIONS WE INFORME IT TO HOD.
3. checked v belts condition and inform if its on critical stage. IT IS OK.
4. checked foundation bolts and nuts of Plummer blocks.
5. greasing the Plummer blocks is done.
6. checked the duct condition and remove dust from the duct. it is ok.
7. check stack condition and check its temperature. it is ok.
Remark
FurnaceOther
StatusCompleted