Maintenance Details
| Date | 14 May 2020 |
|---|---|
| Start Time | 07:30:15 |
| End Time | 08:30:15 |
| Nature Of Maintenance | Mechanical |
| Equipment | POLLUTION 1 |
| Type of Maintenance | Scheduled Maintenance |
| Details | POLLUTION ID FANS (Furnace 1) 1. open cover and clean dust.clean and balancing is done. 2. check the balancing of impeller and vibration isolation.it is ok. 3. check v belts condition and inform if it's on critical stage.4nos belt is broken so we change it. belt no is 4450 4. check foundation bolts and nuts of Plummer blocks.it is ok. 5. greasing the Plummer blocks.greasing is done. 6. check the duct condition and remove dust from the duct. 7. check stack condition and check its temperature. it is ok. |
| Remark | (not set) |
| Furnace | Other |
| Status | Completed |