Maintenance Details


Date12 May 2020
Start Time08:25:15
End Time08:50:15
Nature Of MaintenanceMechanical
EquipmentELECTRODE 1
Type of MaintenanceBreakdown Shutdown
DetailsIts pressure bolt is tight too much. Thats why electrode shlipping problem is coming. So we loose pressure bolts and after that slipping is done easily.
Remark(not set)
FurnaceFurnace II
StatusCompleted