Maintenance Details


Date08 May 2020
Start Time09:00:30
End Time12:30:30
Nature Of MaintenanceMechanical
EquipmentCHARGING CHUTES
Type of MaintenanceScheduled Maintenance
Details1.checked solenoid valve condition and its pipe condition.it is ok.
2.checked pneumatic cylinders and air supply line.it is ok.
3. some charging chute hole passage is narrow. so some big stones are stuck in the chute pipeline. we inform it to HOD.
Remark(not set)
FurnaceFurnace II
StatusCompleted