Maintenance Details


Date30 Dec 2021
Start Time12:20:05
End Time13:40:05
Nature Of MaintenanceMechanical
EquipmentELECTRODE 1
Type of MaintenanceBreakdown Shutdown
Detailsits electrode 1 side water leakage coming. we are switch off furnace to check it and we found that its coming from 2nd floor. than we check on 2nd floor and found that one pressure ring pipe line has a lot of holes where from the water coming. than we weld .we also found that another reassure ring pipe is damaged we also weld it.
on that time we weld Cooglling tower pipe line. and change pump number 1 to 2.
Remark
FurnaceFurnace I
StatusCompleted