Maintenance Details
| Date | 26 Mar 2021 |
|---|---|
| Start Time | 00:00:30 |
| End Time | 03:00:30 |
| Nature Of Maintenance | Mechanical |
| Equipment | Electrode cooling blower F2 (spare) |
| Type of Maintenance | Breakdown Maintenance |
| Details | It's motor is burn. After that new motor fitting with new gear coupling. Motor specification 10hp 900 rpm. Gear coupling 103 Also it's pipe line welding work is done. Now it's connected with all of the electrodes of f2. |
| Remark | |
| Furnace | Furnace II |
| Status | Completed |