Maintenance Details


Date11 Sep 2020
Start Time07:30:01
End Time16:30:01
Nature Of MaintenanceMechanical
EquipmentHYDRAULIC POWER PACK NO. 2
Type of MaintenanceScheduled Maintenance
Details1. checking loose parts and check the hydraulic oil level in the tank.level is ok. hoisting oil level is showing low. we open it and check and find that the cylinders are open so the oil level indicator showing low.
2. check solenoid valve working conditions and adjust oil pressure.its ok.
3. check hydraulic line leakage. small leakage in one cylinder. we tight next shutdown.
Remark
FurnaceFurnace II
StatusCompleted