Maintenance Details
| Date | 11 Sep 2020 |
|---|---|
| Start Time | 07:30:01 |
| End Time | 16:30:01 |
| Nature Of Maintenance | Mechanical |
| Equipment | HYDRAULIC POWER PACK NO. 2 |
| Type of Maintenance | Scheduled Maintenance |
| Details | 1. checking loose parts and check the hydraulic oil level in the tank.level is ok. hoisting oil level is showing low. we open it and check and find that the cylinders are open so the oil level indicator showing low. 2. check solenoid valve working conditions and adjust oil pressure.its ok. 3. check hydraulic line leakage. small leakage in one cylinder. we tight next shutdown. |
| Remark | |
| Furnace | Furnace II |
| Status | Completed |