Maintenance Details


Date16 Jul 2020
Start Time07:30:01
End Time13:30:01
Nature Of MaintenanceMechanical
EquipmentPOLLUTION 2
Type of MaintenanceScheduled Maintenance
DetailsPOLLUTION ID FANS FOR (Furnace 2)
1. open cover and clean dust.clean.
2. check the balancing of impeller and vibration isolation. vibration coming because of id fan impeller is filled with dust.
3. check v belts condition and inform if its on critical stage. it ok.
4. check foundation bolts and nuts of Plummer blocks. it's ok. we tight it.
5. greasing the Plummer blocks. it's done.
6. check the duct condition and remove dust from the duct.
7. check stack condition and check its temperature. its ok.
Remark
FurnaceOther
StatusCompleted