Maintenance Details


Date26 Jun 2020
Start Time07:30:01
End Time09:00:01
Nature Of MaintenanceMechanical
EquipmentCHARGING CHUTES
Type of MaintenanceScheduled Maintenance
Details1.check solenoid valve condition and its pipe condition.no. 1 and n0. 2 chutes solenoid is not working. we change no1. chute solenoid and repairs no.2 solenoid valve.
we repair no.3 chute cylinder leakage.
2.check pneumatic cylinders and air supply lines.it is ok.
3. check charging chute leakage. if it is than inform HOD.small lekage in no. 1 and no. 3 chutes line. we repair it. now its ok.
Remark
FurnaceFurnace I
StatusCompleted