Maintenance Details
| Date | 26 Jun 2020 |
|---|---|
| Start Time | 07:30:01 |
| End Time | 09:00:01 |
| Nature Of Maintenance | Mechanical |
| Equipment | CHARGING CHUTES |
| Type of Maintenance | Scheduled Maintenance |
| Details | 1.check solenoid valve condition and its pipe condition.no. 1 and n0. 2 chutes solenoid is not working. we change no1. chute solenoid and repairs no.2 solenoid valve. we repair no.3 chute cylinder leakage. 2.check pneumatic cylinders and air supply lines.it is ok. 3. check charging chute leakage. if it is than inform HOD.small lekage in no. 1 and no. 3 chutes line. we repair it. now its ok. |
| Remark | |
| Furnace | Furnace I |
| Status | Completed |